xing icon 32x32        

FIT & SFC Releases 2017

Overview releases 2017

Shop Floor Connect for Teamcenter Release 2017.4 - October 2017

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity).

All customers who do not have access to our CIC platform and want to download the software over CIC have to require access over the following link: » Login or registration customer center

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium. Direct Siemens PLM Software customers can get the release from the GTAC download area.

This Shop Floor Connect Release 2017.4 supports all Teamcenter UA versions from 9.x up to the Teamcenter versions 11.x.

Service notice

  • DNC Connect only supports the actual NX versions who are under maintenance from Siemens (please see attached the "End of Maintenance attachemnts for NX and Teamcenter).
  • For customers who want to update on the Teamcenter 11.3 version: From TC 11.3 and on, a new license verification will be done upon the creation of manufacturing objects like MEProcess, MEOP, MEWorkArea and their sub-types (including custom types). This check will be done on server side per Teamcenter policy and to ensure license verification. It will use two new feature keys: 1) mfg_planning_lite for verifying MEProcess, MEOP and their sub-types 2) mfg_plant_author for verifying MEWorkArea and its sub-types.
    This new license check will be done in addition to other license verification that exists today. If you don't find them in your Teamcenter 11.3 license key please get in contact with Siemens PLM.

Shop Floor Connect/API

Enhancements

  • SFC-WebClient can now use Teamcenter Security Service (TCSS) for user login.
  • Logfiles soap_log.txt and tcdnc_log.txt replaced by SFC-Core.log.txt.
  • New API functions: SFC_LoginSSO_20174 and SFC_Login_20174.
  • New API function SFC_RequestSFCWorkpackage_20174 to request SFCWorkpackage in JSON format.

Bugfixes/Changes

  • Fixed an issue where datasets of a deleted DNC type from a workplace specific configuration still have been found and shown.
  • Fixed a refresh problem in SFC_RequestSFCWorkpackage_20152 to access new created activity folders of an existing MENCMachining Revision within an other TC session.
  • New log file "SFC-WebClient.log.txt". The "old" Webclient will write logging messages now in this file instead of "tomcat.log".
  • The configuration data of used dataset types for a DNC type is now stored in a Text dataset. The forms of type "AplusB DNC Datatype" will not be used anymore - except for already stored configurations.
  • Upgrade of the internal Java to version 1.8.0_144 (only Windows).


MI-Server

Bugfixes/Changes

  • Additional configuration property WaitUntilSendBufferIsEmpty.InitialWaitTime to fix issue where "Transfer ready" status was reported while serial transfer was still in progress. This is only an issue with WuT COMServer++, Firmware 1.40 and newer.


Subject to change without notice.

 

FIT Release 2017.4 - October 2017

The new FIT Release 2017.4 is now available and released for Microsoft Windows platform. Please look below for the enhancements and changes of the different modules.

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity). All customers who have no access to our CIC platform and want to download the software over CIC have to require access over the following Link an.

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium.

The FIT modules as well as all additional modules are released for the Microsoft operating system Windows 2012 and 2016 Server (also Version R2) as well Windows 7, 8 and 10. We support also the databases Microsoft SQL Server 2012, 2014, 2016 and Oracle 12c.

FIT-MI-Server

Bugfixes/Changes

  • Additional configuration property WaitUntilSendBufferIsEmpty.InitialWaitTime to fix issue where "Transfer ready" status was reported while serial transfer was still in progress. This is only an issue with WuT COMServer++, Firmware 1.40 and newer.


FIT-HI-Server

Enhancements

  • When detecting the Windows user logged on now additional debug messages are written to the log files.
  • In the request and upload phase now a number of additional data fields can be used.

Bugfixes/Changes

  • With record modifications via the FIT-WebMenu the user was not written to the FIT logbook. This has been fixed.


FIT-HI-WebMenu

Enhancements

  • It is now possible to configure which fields are to be transferred to ExcelLive and whether the 'Save' button should be displayed.
  • In the administration now a systeminfo with a listing of the installed software versions can be displayed and saved as a text file.
  • Now in the search results list (parts, orders, or time data) per line a preview image can be displayed (if a image is available).
  • In the search form now a help can be displayed.

Bugfixes/Changes

  • The automatic logon with the current windows user didn't work anymore with newer versions of Internet Explorer. This problem has been resolved.
  • ExcelLive now works with HTTPS.
  • CleanDataExecutor can be configured in process.dat to delete Excel-Live-Data for inactive sessions.


FIT-HI-MES

Enhancements

  • In operation mode assembly it is now possible to prevent that one person processes multiple orders/order groups at a time.
  • It is now possible to write the calculated rest quantity to a OPC UA variable.
  • It is now possible to start FIT-HI-DNC with a different file preselection dependent on signal status.

Bugfixes/Changes

  • With action failure booking under certain circumstances time data records were not properly closed. This problem has been resolved.
  • In operation mode assembly with action orderreportcompletion the durations were not distiributed correctly.This problem has been resolved.
  • In operation mode order report with certain configurations the cursor had not been set into the first input box automatically. This problem has been resolved.


FIT-AnalyseTool

Enhancements

  • In the report "Analyse MDA data" the activities with duration =0 are no longer listed in the graphic.
  • The temporary files "*.jpg" from the "chart"-directory are now automatically deleted.
  • Open time records can be considered.


Subject to change without notice.

FIT Release 2017.3 - July 2017

The new FIT Release 2017.3 is now available and released for Microsoft Windows platform. Please look below for the enhancements and changes of the different modules.

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity). All customers who have no access to our CIC platform and want to download the software over CIC have to require access over the following Link an.

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium.

The FIT modules as well as all additional modules are released for the Microsoft operating system Windows 2012 and 2016 Server (also Version R2) as well Windows 7, 8 and 10. We support also the databases Microsoft SQL Server 2012, 2014, 2016 and Oracle 12c.

FIT-Server

Enhancements

  • Optimization of the versioning process for part data in the standard part data interface.


FIT-MI-Server

Enhancements

  • Update internal Apache Tomcat to 8.5.15.


FIT-HI-Server

Enhancements

  • The FIT-HI-Server now uses Tomcat version 8.5.15.

Bugfixes/Changes

  • Under certain circumstances configuration data regarding the part files was damaged in memory. This lead to problems uploading certain file types. This problem has been resolved.


FIT-CAMIntegrator

Enhancements

  • When adding several files in a directory to a zip file now multiple patterns for the files to be processed can be specified, e. g. in order to add files with different extensions.


FIT-HI-WebMenu

Enhancements

  • It is now possible to download the log files from the FIT server in FIT-HI-WebMenu
  • The licence overview now also lists the number of licences used per application. The list of HI sessions is now sortable.
  • The function to view the FIT logbook has been moved underneath the menu item administration.
  • In shop floor and detail views of the InfoCenter now configurable current actions can be displayed with further data fields.

Bugfixes/Changes

  • When searching corresponding records of another module, e. g. corresponding time data to an order, no data had been found if the linked data field contained leading spaces. This problem has been resolved.
  • Displaying the FIT logbook didn't work on HTTPS connections. This problem has been resolved.
  • Some minor display errors with the file comparison and parallel editor have been fixed.
  • Minor display errors when starting to edit a record have been resolved.
  • Display errors when viewing files from the corresponding original or upload record have been resolved.

FIT-HI-MES

Enhancements

  • Now a clearly-identifiable description can be set for OPC UA targets (servers).
  • The reason for scrap must be specified now if a scrap quantity > 0 is reported.

Bugfixes/Changes

  • Determining the allocated workplaces failed in some cases as the hostname of the client PC could not be detected. This problem has been resolved.
  • In rare cases configuration errors of a single workplace lead to malfunctions of other workplaces. This problem has been fixed.
  • With multiple OPC UA signal with additional OPC UA variables to read at one workplace under certain circumstances wrong values had been read. This problem has been resolved.
  • With workplaces of operation mode manufacturing with multi scrap configuration errors occurred with failure reporting. This problem has been resolved.
  • Booking of yield quantities with action "quantity reporting multiple tables" didn't work anymore. This problem has been resolved.
  • FIT-HI-MES has been adjusted for usage with Tomcat 8.5.
  • The FIT-HI-MES Administration now prevents creating an order request element without a caption.
  • In operation mode manufacturing in conjunction with a barcode field the view leapt to a wrong position when a functionkey was clicked. This problem has been resolved.


FIT-HI-DNC

Enhancements

  • The confirmation dialog to overwrite an existing upload record now displayed detailed information about this record.

Bugfixes/Changes

  • Minor display errors in the copy part record function have been fixed.


FIT-CapaTool

Enhancements

  • JGantt license is now checked per CapaTool user.
  • Local setting is now stored in user.home Folder instead of 'Desktop'.
  • Analyse view works now with JGantt version 3.1 and 3.2.

Bugfixes/Changes

  • Flags red / yellow / green as indicators for observance the completion date (as in order explorer) are now also displayed in order stock lists.

For any further question don't hesitate to contact us.

FIT Release 2017.2 - April 2017

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity). All customers who have no access to our CIC platform and want to download the software over CIC have to require access over the following Link an.

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium.

The FIT modules as well as all additional modules are released for the Microsoft operating system Windows 2012 Server (also Version R2) as well Windows 7, 8 and 10. We support also the databases Microsoft SQL Server 2012, 2014, 2016 and Oracle 12c.

FIT-HI-WebMenu

Enhancements

  • In the custom_templates folders masks with all fields are available.
  • A graphic can now also be displayed in the print view of files.
  • User management is now available in WebMenu.

Bugfixes/Changes

  • The mask set selection was not displayed correctly while using the compatibility view in Internet Explorer. This problem has been resolved.


FIT-HI-MES

Enhancements

  • It is now possible to browse the address space of an OPC UA server from within FIT-HI MES Administration to select nodes for reading and writing directly. The node id needn't be typed anymore.
  • A tool for creation of self-signed certificates for usage with OPC UA is now provided with FIT-HI-MES.
  • Path and filename of the certificate used for communication via OPC-UA are now configurable.
  • It is now also possible to write variables via OPC-UA, e. g. in order to set a digital output upon when a signal turns on or a key is pressed. Besides specified values also values from the order or part record can be written, as well as QSYS serial numbers.
  • In FIT-HI-MES Administration it is now possible to restart the input processor thread for a workplace in operation mode manufacturing.
  • For OPC UA signal, condition can now be defined which determines when the signal is on or off.
  • The transportation record print file includes the information of the subsequent operation.

Bugfixes/Changes

  • Compatibility issues accessing OPC UA servers from Siemens and Kepware have been resolved.


FIT-AnalyseTool

Bugfixes/Changes

  • The error in the calculation for "Analyse MDA data" has been fixed.


FIT-CapaTool

Enhancements

  • The order can be rescheduled with status change.

For any further question don't hesitate to contact us.

Shop Floor Connect for Teamcenter Release 2017.1 - February 2017

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity).

All customers who do not have access to our CIC platform and want to download the software over CIC have to require access over the following link: » Login or registration customer center

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium. Direct Siemens PLM Software customers can get the release from the GTAC download area.

This Shop Floor Connect Release 2017.1 supports all Teamcenter UA versions from 8.x up to the actual version Teamcenter 11.2.

Shop Floor Connect

Enhancements

  • Added support of new serial operation mode "Virtual COM" of the Machine Tool Client. Local COM ports (virtual COM ports too) can now be used. MI-Server Version 2016.3 or newer required.
  • New API function SFC_RM_RequestResourcePackage_20171 to retrieve a classified manufacturing resource (for example MRL Tool).
  • New API function SFC_DataManagement_SendEnvelope_20171 to send a Teamcenter Envelope.

Bugfixes/Changes

  • SFCWorkplace is now insert setting BOMLine property "UG GEOMETRY"="NO" into BOM of a new created MENCMachining Revision.


MI-Server

Enhancements

  • Virtual COM ports are now supported.
  • It is possible to configure MI Server to merge transfered file with TOOL.T file on Heidenhain control.
  • For the S840D control, the long NC program names are displayed for the selection process.
  • dhinf.000 is hidden.

Bugfixes/Changes

  • Parity and frame error will be recognized at data transfer using virtual COM.#
  • When starting VirtualCOM and there was no connection to a COM-Port, VirtualCom remained in the StartWA-Thread and continuosly tried to establish a connection. This issue is fixed.
  • Some transfer issues via UDP packages are fixed now.


Subject to change without notice.

 

Shop Floor Connect for Teamcenter Release 2017.2 - April 2017

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity).

All customers who do not have access to our CIC platform and want to download the software over CIC have to require access over the following link: » Login or registration customer center

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium. Direct Siemens PLM Software customers can get the release from the GTAC download area.

This Shop Floor Connect Release 2017.2 supports all Teamcenter UA versions from 8.x up to the actual version Teamcenter 11.2.


Shop Floor Connect

Enhancements

  • If the SPLM license server is not reachable during login to Teamcenter, the received error message "Error attaching to FLEXlm" of type "InvalidCredentialsException" is now classified as a connection problem to Teamcenter and will be handled as a failover reason.
  • Failover: The configured and calculated timeout values for the automatic switch into failover are now written in the logfile if the automatic swtich is enabled.
  • After login to Teamcenter additional information like site id and TCServerLocale are written into SFC logfile after the name of the assigned tcserver.syslog file.
  • Fixed an issue in IMAN_Operation-Mode 3. It was not possible to create a new CAM item targeting an exiting CAD item if a CAM item for an other workplace is already assigned to the CAD item.
  • New API function SFC_RequestSFCWorkpackage_20172.

Bugfixes/Changes

  • Fixed an issue in SFC_RM_ImportPresetterMeasuringProgramFile_20163. The function returns now the values described in the API documentation instead of value 0.
  • Fix for "Invalid character found in the request target. The valid characters are defined in RFC 7230 and RFC 3986". This is required to prepare Webpages for Tomcat update.
    If you use modified templates please check that no JavaScript URL parameter contains a | character. All parameters containing this character must be encoded using JavaScript function encodeURI(what)!
    See also README_SFC.txt on the installation media for more details.
  • Update internal Apache Tomcat to 7.0.76
  • Button "Reload datatypes" removed from Admin-HI. This function is not required anymore. "Reload configuration" should be used instead to read configuration into SFC if modified in Teamcenter RAC.
  • Optimized failover detection. New configuration properties added to set connection timeout values to interrupt a running and not responding Teamcenter request.

    This can occur if Teamcenter server manager is running but the database engine is not running or reachable.
    The new properties are:
    OPT_SERVER_TIMEOUT.SOA_ManagementRequests
    OPT_SERVER_TIMEOUT.SOA_DataRequests and
    OPT_CONNECTION_TIMEOUT.

MI-Server

Enhancements

  • Update internal Apache Tomcat to 7.0.76


Subject to change without notice!

Shop Floor Connect for Teamcenter Release 2017.3 - August 2017

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity).

All customers who do not have access to our CIC platform and want to download the software over CIC have to require access over the following link: » Login or registration customer center

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium. Direct Siemens PLM Software customers can get the release from the GTAC download area.

This Shop Floor Connect Release 2017.3 supports all Teamcenter UA versions from 9.x up to the Teamcenter versions 11.x.


Service notice

  • The Teamcenter 8.x UA versions will be not supported from this version of Shop Floor Connect.
  • DNC Connect only supports the actual NX versions who are under maintenance from Siemens (please see attached the "End of Maintenance attachemnts for NX and Teamcenter).
  • For customers who want to update on the Teamcenter 11.3 version: From TC 11.3 and on, a new license verification will be done upon the creation of manufacturing objects like MEProcess, MEOP, MEWorkArea and their sub-types (including custom types). This check will be done on server side per Teamcenter policy and to ensure license verification. It will use two new feature keys: 1) mfg_planning_lite for verifying MEProcess, MEOP and their sub-types  2) mfg_plant_author for verifying MEWorkArea and its sub-types.
    This new license check will be done in addition to other license verification that exists today. If you don't find them in your Teamcenter 11.3 license key please get in contact with Siemens PLM.


Shop Floor Connect / DNC Connect / API

Enhancements

  • New configuration property "Workplace type" to define type of the current workplace. This can be for example "configuration workplace".
  • MI administration: List of workplaces in MI configuration now contains only workplaces of type "Workplaces with Machineinterfaces".
  • New workplace type value "inactive".
  • Workplaces of type 'configuration' and 'inactive' are not included in list of selectable workplaces anymore.
  • Update internal Apache Tomcat to 8.5.15.
  • New API function SFC_IsInFailoverMode to check if SFC is in failover mode.
  • New API function SFC_RM_SearchClassification_20173 to search in classification.
  • New API function SFC_ExportAssembly_20173 to export a (NX-) assembly from Teamcenter.
  • New API function SFC_DataManagement_ListFolderContents_20173 to get contents of a folder.
  • New API function SFC_DataTransfer_GetTransferStatus_20173 to get transfer status information of a MTC.
  • Change of Tomcat memory configuration: Remove of -Xmx512m and add -XX:MaxPermSize=256m. This change is required to host additional ActiveDNC web app. Linux installation requires a manual edit of file /Tomcat 5.0/bin/setenv.sh: Remove -Xmx512m from JAVA_OPTS line if not already done.
  • For Early Adaptors. First version of the new WebClient to get a first impression of the new Active Workspace look and feel client. Not all functions of the "old" WebClients are available. Should be used only for testing. Open with URL http://localhost:8888/ActiveDNC

Bugfixes/Changes

  • Fixed an issue where SFC was stopping working when a non existing file (wrong file name, misspelled or not copied) should be imported with partinterface. SFC checks now if the file is really available and readable before calling Teamcenter SOA function to import file and returns an error message if file is not readable.
  • Fixed an issue where SOA_00214009: [An IFail was thrown unexpectedly.] was received if directly after importing the default DNC-Setup folder a MI should be created in MI administration.
  • Fixed an issue where SFC was not able to update its counfiguration datasets of a DNC type when display name for dataset type "Text" is modified.
  • WebClient can now detect used format of UGCAMShopDoc and select best presentation option (HTML, PDF, Text, ...). To enable automatic detection after update, the configuration checkbox "compressed view" for UGCAMShopDoc dataset must be deselected.
  • Error 'The given tag () does not exist in the database or is not a persistent object tag.' could occur if the target object where SFC should paste a new object into was modified in an other Teamcenter session. This is now fixed performing a refresh on target before execute paste operation.
  • Fixed an issue where a new created DNC type disappears after a 'reload configuration'.
  • Webclient detect now stored file format of UGCAMShopDoc and displays either HTML, PDF or Text file CompressedView configuration (DNCTypes) must be disabled to enable this new feature.
  • Fixed an issue where a modified workplace configuration setting via tcw/admin was overwritten with an older value after perform a 'reload configuration' from Teamcenter.
  • Fixed an issue where SFC_RM_RequestUsedToolList_20163 did not find the ItemRevision when the activity folder where the NC dataset is attached was previously renamed.
  • Fixed an issue where a wildcard query for Items failed with error NoItemRevisionFoundForRevisionRule if ItemRevision of a Item could not be loaded by Teamcenter revision rule. In this case now a error message is only written in log file and all other found ItemRevisions will be returned.
  • New configuration key ShowFile.[DNCType].CharacterEncoding to define character encoding send from WebServer to Webclient to be used to show HTML page content. Can be used if, for example, HTML ShopDoc files are stored in ISO-8859-1 instead UTF-8 character set.
  • SFC workplace configuration is now stored in a dataset of type Text. The form of type "AplusB Workplace Config" is not created anymore. Existing forms will still be read. If configuration is modified, the form is converted to new dataset.


MI-Server

Bugfixes/Changes

  • Update internal Apache Tomcat to 8.5.15.

Subject to change without notice!

 

 

FIT Release 2017.1 - January 2017

The new FIT Release 2017.1 is now available and released for Microsoft Windows platform. Please look below for the enhancements and changes of the different modules.

The release is available for all customers with maintenance agreement and access to our Customer Information Center (CIC) for download (please create a release activity). All customers who have no access to our CIC platform and want to download the software over CIC have to require access over the following Link an.

Please send an email to This email address is being protected from spambots. You need JavaScript enabled to view it. if you want the release on a data medium.

The FIT modules as well as all additional modules are released for the Microsoft operating system Windows 2012 Server (also Version R2) as well Windows 7, 8 and 10. We support also the databases Microsoft SQL Server 2012, 2014, 2016 and Oracle 12c.


FIT-Server

Enhancements

  • Windows Server 2016 is now supported.
  • Windows 8.1 is now supported.


FIT-MI-Server

Enhancements

  • dhinf.000 is hidden.
  • Virtual COM ports are now supported.
  • It is possible to configure MI Server to merge transfered file with TOOL.T file on Heidenhain control.
  • For the S840D control, the long NC program names are displayed for the selection process.

Bugfixes/Changes

  • Parity and frame error will be recognized at data transfer using virtual COM.
  • When starting VirtualCOM and there was no connection to a COM-Port, VirtualCom remained in the StartWA-Thread and continuosly tried to establish a connection. This issue is fixed.
  • Some transfer issues via UDP packages are fixed now.


FIT-HI-Server

Bugfixes/Changes

  • With certain database queries to Microsoft SQL Server via ODBC errors occurred, e. g. when configuring fields of the upload dialog in FIT-MI-Administration. This problem has been resolved.
  • If the file storage location was not configured as a subdirectory of the FIT directory uploads of nc programs failed. This problem has been solved.
  • After upgrading to Tomcat 7, the old Tomcat 6 home page was still displayed. This problem has been fixed.


FIT-CAMIntegrator

Enhancements

  • FIT-CAMIntegrator has been optimized for Java 8. It is now no longer runnable on previous Java versions, therefore a FIT-HI-Server of V2015.4 or higher is required.


FIT-HI-WebMenu

Enhancements

  • FIT-HI-Webmenu has been optimized for Java 8. It is now no longer runnable on previous Java versions, therefore a FIT-HI-Server of V2015.4 or higher is required.
  • In version 2016.4 manual configuration was necessary to start the FIT-Logbook from the FIT-HI-WebMenu. Now the FIT-Logbook is automatically available with the standard installation.
  • Select boxes with options separated into groups (group-first mode) can now also be used without an additional display text defined in the configuration.
  • The renumber of NC programs can be restarted based on special indicators so that the renumber process at all programs is starting with the start value.
  • Editor for double listing.

Bugfixes/Changes

  • The workplaces module had been displayed in the main menu regardless of the user's permission to start the part data administration. This has been corrected.


FIT-HI-MES

Enhancements

  • FIT-HI-MES has been optimized for Java 8. It is now no longer runnable on previous Java versions, therefore a FIT-HI-Server of V2015.4 or higher is required.
  • A shipment document for the committee can now be printed for the reject report.
  • When QSYS orders are returned, the difference between QSYS released quantity and current actual quantity can now be reported.
  • For the QSYS connection, it is now configurable which field of the FIT order data table contains the operation.
  • It is now also possible to book a predefined user or ID number with a function key or signal.
  • It is now possible to configure a combined status display (red/green circle) that checks a condition for the current operation in addition to the predecessor status.
  • "Print paycheck" signal action is now booked as an activity.
  • You can now define the conditions for which orders a pay slip is to be printed.

Bugfixes/Changes

  • The CASQ check didn't work any more in V2016.1 and later. This problem has been resolved.
  • In V2016.4 occasionally the function keys remained white and orders were not displayed any more. This problem has been resolved.
  • In the multiple tables view the selected table had often not been displayed as selected any more. This problem has been resolved.
  • In FIT-HI-MES Administration some display errors of tool tip information about the signal configuration have been fixed.


FIT-HI-DNC

Enhancements

  • FIT-HI-DNC has been optimized for Java 8. It is now no longer runnable on previous Java versions, therefore a FIT-HI-Server of V2015.4 or higher is required.
  • Operating mode "Virtual COM".


FIT-AnalyseTool

Enhancements

  • FIT-AnalyseTool has been optimized for Java 8. It is now no longer runnable on previous Java versions, therefore a FIT-HI-Server of V2015.4 or higher is required.


FIT-CapaTool

Enhancements

  • When entering non-availability times of the machines, a type (leave, sick, ...) and the person (as reason) can now be selected.
  • In the personnel master data, a button Start of work appears, which can then be used to define the start of work for the selected person

For any further question don't hesitate to contact us.