New FIT-Release 2011.4 available - please call for CD or download

 

The release, we provide all customers with maintenance contracts and access to our Customer Information Center (CIC) for download in the FAQ area. Please create an issue with the release request to obtain the corresponding password. All customers with a maintenance contract, which still have no access to our CIC platform and want to download the software have to request for access. Please follow this link. If you need the release of a CD / DVD, then please send us an email to our service, or note it accordingly if you create a CIC process.

The FIT modules as well all addtitional modules are released for the Microsoft operating system Windows 2008 Server and Windows 7. We support also the databases Microsoft SQL Server 2008 and Oracle 11g.

 

The following issues are fixed:

 

FIT
===

 

FIT-Server
--------------

Bugfixes/changes:
-------------------------
-   When installing the FIT-Server, the environment variable "PATH" no longer will be truncated to a length of
512 characters. The length of the PATH-variable now can be max. 2048 characters.


FIT-MI-Server
-----------------

Enhancements:
----------------------
-  It's now possible to set the configured system password of a WuT COMServer in mi_server.ini with parameter "WuTSystemPassword".
- When an NC program is sent via AutoDNC to a directly connected machine the part number of the FIT part record was previously used as the file name. As of version 2011.3 it is possible to specify FIT part record field to be used for file name creation. For more information please see "Filename configuration" in chapter AutoDNC.
- The MI option "CompressDirForDNCType" is now also available for machine tools connected via FTP.
-  Logfile mi_transfer_log.txt for transfered files is now active by default.
- Logfiles of a new installed FIT-MI-Server will now be written into directory %FITDIR%/run/log/FIT-MI_Server/
 A update will not change logging configuration of a already installed FIT-MI-Server.
- It's now possible with LAN AutoDNC to create a status file in the exchange directory after the MI found the AutoDNC command file. This file will be deleted after the transfer of DNC data was ended. So the operator can see if AutoDNC is running or already completed. See 'Configure Transfer Status file' in chapter 'AutoDNC'.

Bugfixes/changes:
-------------------------
- No error file was send to machine if an error occurred while a compressed directory
(option "CompressDirforDNCType") was requested via AutoDNC. This bug has been fixed. Now the error file will be send if configured.
-  In the directory listing of a machine connected via FTP, it could happen that the complete path and not just the file
name was displayed. This bug has been fixed. There are now only displayed the file names in the selected directory.
- It was possible under certain circumstances, to start two instances of the MI by double-clicking the Start button on the MI-control. These two instances have interrupted each other the connection to the COM server. This problem is solved.
-  If the installation path of Heidenhain TNCRemoNT Software contains space character, the MI wasn't able to get the directory listing on the control. This problem was solved.
-  As of Windows Server 2008R2 the error message for a already  used TCP/IP port has been changed. If the MI can't connect to the COM-Server, a retry will be done after a few milliseconds. 2008R2 Server signals this error with the following message "Unrecognized Windows Sockets error: 0: Cannot bind"
The message will now be catched and internally processed.


FIT-HI-Server
-----------------

Enhancements:
----------------------
- When uploading a file with upload revisioning activated now the files of the previous revision can be copied into the new revision.
- It is now possible to define a status that is retained when uploading. If a part has this status when uploading the
upload records are created with this status, too.

Bugfixes/changes:
-------------------------
- When creating new time data in FIT-HI WebMenu only one record was created, then the action was aborted with an error message.


FIT-HI-Webmenu
-----------------------

Enhancements:
----------------------
- From the order detail view it is now also possible to switch to the corresponding part and vice
versa.
- Changes to lodged files via FIT-HI WebMenu can now be logged in a separate file.
- In part data administration the sort sequence was changed so that like in FIT-HI DNC the original records are displayed before the upload records.
- In InfoCenter pressed keys are now displayed in the same color as in FIT-HI-MES.
- Russian language files covering the part data administration are now included. There is now a possibility to use languages with character sets other than ISO-8859-1 for file types, field identifiers and ncp status denominations as well. Customer specific modifications in TextResource_user.properties are now applied without restarting the FIT-Tomcat service.
-  It is now possible to define a status that is retained when uploading. If a part has this status when uploading the
upload records are created with this status too.

Bugfixes/changes:
-------------------------
-  The session in FIT-HI WebMenu is now kept more reliably. Before the session was often lost.
-  In order detail view the field "Failure source" was displayed instead of the field "Expected duration". This has been corrected.


FIT-HI-DNC
----------------

Enhancements:
----------------------
- On reporting back the different file types can now be uploaded into different records, i. e. for every file type a
separate reporting dialog can be displayed.
- Russian language files are now included. There is now a possibility to use languages with character sets other than ISO-8859-1 for file types, field identifiers and ncp status denominations as well. Customer specific modifications in TextResource_user.properties are now applied without restarting the FIT-Tomcat service.
- Up to now existing space characters in the nc filename was replaced by a underscore.It's now possible to configure this character with the new parameter 'SpaceReplaceChar'.
See chapter 'Filenames in a direct connection' in FIT-HI-DNC documentation.

Bugfixes/changes:
-------------------------
- When viewing binary files e. g. Microsoft Office documents in FIT-HI DNC now the same file extension as on the FIT server is used (Requires a FIT-HI Server of V2011.3 or higher).
- In some cases problems occured when using a proxy server. Then the selection of the workplace didn't work properly. This problem has been resolved.


Subject to change without notice!

 

FIT
===

FIT-Server
--------------

Bugfixes/Anpassungen:
--------------------------------
- Problembehebung beim Einlagern von Aufträgen mit '-Zeichen :
das '-Zeichen wird nun durch ein Leerzeichen ersetzt.


FIT-MI-Server
-----------------

Erweiterungen:
--------------------
- Die Parameter "StoreRecvDataToFile" und "StoreSendDataToFile" können jetzt auch bei einer Direktanbindung gesetzt werden.


Bugfixes/Anpassungen:
--------------------------------
- Das einzelne FIT-MI konnte manchmal im FIT-Modus nur noch durch einen Neustart des FIT-MI Tomcat Dienstes durchgeführt werden. Der Neustart über das FIT-HI hatte keinen Erfolg.
Es sind jetzt zusätzliche Überprüfungen und Meldungen eingefügt worden.
- AutoDNC kann jetzt auch über eine FTP-Anbindung erfolgen. Dazu muss auf der Maschine ein FTP-Server laufen der angesprochen werden kann.
- Logmeldungen für den AutoDNC-Modus waren teilweise nur auf Deutsch. Die englische Übersetzung wurde zusätzlich eingefügt.


FIT-HI-Server
-----------------

Erweiterungen:
--------------------
- Bei aktivierter Uploadrevisionierung können nun beim Upload einer Datei die Dateien aus der vorhergehenden Revision mit kopiert werden.



FIT-HI-Webmenü
-----------------------

Erweiterungen:
--------------------
- Aus der Auftragsdetailansicht ist nun auch der Sprung zum korrespondierenden Teil möglich und umgekehrt.
- Änderungen an hinterlegten Dateien über FIT-HI-WebMenü können nun in einer separaten Datei protokolliert werden.
- In der Teiledatenverwaltung wurde die Sortierung so geändert, dass wie in FIT-HI-DNC die Originaldatensätze vor den Uploaddatensätzen angezeigt werden.
- Im FIT-HI-Webmenü-InfoCenter werden nun die gedrückten Funktionstasten in derselben Farbe dargestellt wie im FIT-HI MES.
- Es werden nun russische Sprachdateien mitausgeliefert, die die Teiledatenverwaltung abdecken.
Auch für Dateitypen, Feldbezeichner und Teilestatusbezeichnungen gibt es nun eine Möglichkeit, Sprachen mit anderen Zeichensätzen als ISO-8859-1 zu verwenden sowie mehrere Sprachen parallel zu verwenden.
Kundenspezifische Anpassungen in TextResource_user.properties werden nun ohne Neustart des FIT-Tomcat-Dienstes übernommen.

Bugfixes/Anpassungen:
---------------------
- Die Sitzung im FIT-HI WebMenü wird nun zuverlässig aufrechterhalten. Zuvor ging die Sitzung teilweise verloren.


FIT-HI-MES
---------------

Erweiterungen:
--------------------
- Pro Arbeitsplatz (Clientadresse) kann nun auch ein grafisches Hallenlayout zur Arbeitsplatzauswahl konfiguriert werden.
- Bei der Aktion 'Palette fertigmelden' wird jetzt nur eine Verbuchung durchgeführt, falls ein Auftrag auf der Palette ist.
- Viele Mobilfunkanbieter ermöglichen die Einrichtung einer Emailadresse für den Versand als SMS. Somit ist auch eine Benachrichtigung per SMS bei Signaleintritt möglich.
- In FIT-HI MES kann nun für jeden Auftrag angezeigt werden, ob noch Vorgängerarbeitsgänge offen sind oder nicht.
- In der Betriebsart Auftragsmeldung ist nun eine Druckansicht mit allen anstehenden Aufträgen verfügbar.
- Das Fähnchen für die Liefertreue kann nun auch im Ergebnis der Auftragssuche angezeigt werden.
- Die Auftragsübersicht kann nun auch für das Ergebnis einer Auftragssuche aufgerufen werden.
- Bei Signaländerungen kann nun eine Benachrichtigung per Email erfolgen. Nachrichtentext und Emailempfänger sind pro Signal konfigurierbar. 

Bugfixes/Anpassungen:
--------------------------------
- Meldungen des WebIO wurden bei bestimmten Zeitabständen zur letzten Signaländerung nicht übermittelt. Dies ist nun behoben.
- Beim Hinzufügen von neuen S7-Variablen wurden die Felder zur Verbuchung nicht gespeichert, erst beim erneuten Ändern wurden die Eingaben vollständig übernommen. Dieses Problem ist nun behoben. Außerdem wird nun bei allen anderen Datentypen als 'Bit' die Bitnummer automatisch auf 0 gesetzt.
- Die Verbuchung auftragsübergreifend übermittelter Parameter per S7- oder SOAP-Signal ist nun möglich.
- Bei MDE-Signalen von WebIOs wurden die Eingänge 8 - 11 nicht richtig ausgewertet. Dieses Problem ist nun behoben.
- Bei der Aktion "Palette fertigmelden" wurden die Aufträge nicht von der Palette entfernt, falls nicht die Sollstückzahl erreicht wurde. Dies ist nun behoben.


FIT-HI-DNC
----------------

Erweiterungen:
---------------------
- Bei der Rückmeldung können nun die einzelnen Datentypen in unterschiedliche Datensätze übertragen werden, d. h. es kann zu jedem Dateityp ein eigener Rückmeldedialog angezeigt werden.
- Es werden nun russische Sprachdateien mitausgeliefert. Auch für Dateitypen, Feldbezeichner und Teilestatusbezeichnungen gibt es nun eine Möglichkeit, Sprachen mit anderen Zeichensätzen als ISO-8859-1 zu verwenden sowie mehrere Sprachen parallel zu verwenden. Kundenspezifische Anpassungen in TextResource_user.properties werden nun ohne Neustart des FIT-Tomcat-Dienstes übernommen.

Bugfixes/Anpassungen:
--------------------------------
- Beim Anzeigen von Binärdateien wie z. B. Microsoft Office-Dokumenten in FIT-HI DNC wird nun dieselbe Dateiendung verwendet, wie auf dem FIT-Server (Voraussetzung ist ein FIT-HI Server ab V2011.3).


AnalyseTool
-----------
Erweiterungen:
--------------
- Die Sprachressourcendateien sind jetzt auch in Englisch und Französischverfügbar.
- Die OEE-Auswertung ist neu dazugekommen.